In-Line Deflagration Flame Arrester concentric design, bidirectional

Características
Función y descripción

Compact Design of the In-Line Deflagration Flame Arrester
The compact design of the PROTEGO® FA-G In-Line Deflagration Flame Arrester makes it the state-of-the-art technology for installation in pipes with diameters of up to 2”. The devices are installed with minimal distance to the burner to prevent flashback into the fuel feed lines. When installing the Deflagration Flame Arrester, make sure that the distance between potential ignition sources and the location of the installed device does not exceed the L/D ratio (pipe length/pipe diameter) for which the device was approved. As per EN ISO 16852, the L/D ratio is limited to (L/D)max ≤ 50 for Deflagration Flame Arresters of explosion groups IIA and IIB3 (NEC groups D and C {MESG ≥ 0.65 mm}) and to (L/D)max ≤ 30 for explosion group IIC (NEC group B).

Main Component – PROTEGO® Flame Arrester Unit
The In-Line Deflagration Flame Arrester is symmetrical and offers bi-directional flame transmission protection. The device consists of two housing parts (1) and a PROTEGO® Flame Arrester Unit or a FLAMEFILTER® (2) and spacers in the center. The number of FLAMEFILTER® discs and their gap size depend on the operating conditions, such as the temperature, pressure, explosion group, and the composition of the fluid. The PROTEGO® FA-G Series In-Line Deflagration Flame Arresters is available for explosion groups IIA, IIB3, and IIC (NEC groups D, C {MESG ≥ 0.65 mm} and B).

Many Individual Certifications
The standard design can be used with an operating temperature of up to+60°C / 140°F and an absolute operating pressure acc. to table 3. Devices with special approval for higher pressures and higher temperatures are available upon request. EU conformity according to the currently valid ATEX directive. Approvals according to other national/international regulations on request.
Dimensiones
To select the nominal size (DN), use the flow capacity charts on the following pages
| DN | G ½" | G ¾" | G 1" | G 1 ¼" | G 1 ½" | G 2" |
| a | 80 / 3.15 | 80 / 3.15 | 100 / 3.94 | 100 / 3.94 | 155 / 6.10 | 155 / 6.10 |
| b | 55 / 2.17 | 55 / 2.17 | 76 / 2.99 | 76 / 2.99 | 124 / 4.88 | 124 / 4.88 |
| c (IIA bis IIB3) | 100 / 3.94 | 100 / 3.94 | 110 / 4.33 | 110 / 4.33 | 170 / 6.69 | 170 / 6.69 |
| c (IIB und IIC) | 112 / 4.41 | 112 / 4.41 | 122 / 4.80 | 122 / 4.80 | 170 / 6.69 | 170 / 6.69 |
| d | — | — | — | — | 400 / 15.75 | 400 / 15.75 |
| SW | 32 / 1.26 | 32 / 1.26 | 50 / 1.97 | 50 / 1.97 | 75 / 2.95 | 75 / 2.95 |
Dimensions in mm / inches, SW= width across flats
Selección de materiales
| Design | B | C |
| Housing | Stainless Steel | Hastelloy |
| Gasket | PTFE | PTFE |
| FLAMEFILTER®* | Stainless Steel | Hastelloy |
* the FLAMEFILTER® is also available in the materials Tantalum, Inconel, Copper, etc. when the listed housing materials are used.
Special materials upon request
Selección del grupo de explosión
| MESG | Expl. Gr. (IEC / CEN) | Gas Group (NEC) |
| > 0,90 mm | IIA | D |
| ≥ 0,65 mm | IIB3 | C |
| < 0,50 mm | IIC | B |
Special approvals upon request
Selección de la máxima presión de operación
| Expl. Gr | DN | G ½" | G ¾" | G 1" | G 1¼" | G 1½" | G 2'' |
| IIA | Pmax | 1,4 / 20.3 | 1,4 / 20.3 | 1,4 / 20.3 | 1,4 / 20.3 | 1,5 / 21.7 | 1,5 / 21.7 |
| IIB3 | Pmax | 1,2 / 17.4 | 1,2 / 17.4 | 1,2 / 17.4 | 1,2 / 17.4 | 1,2 / 17.4 | 1,2 / 17.4 |
| IIC | Pmax | 1,1 / 15.9 | 1,1 / 15.9 | 1,1 / 15.9 | 1,1 / 15.9 | 1,1 / 15.9 | 1,1 / 15.9 |
Pmax = maximum allowable operating pressure in bar / psi absolute, higher operating pressure upon request
Especificación de la máx. temperatura de operación
| ≤ 60°C / 140°F | Tmaximum allowable operating temperature in °C |
| - | Designation |
higher operating temperatures upon request
Tipo de conexión
| Pipe thread DIN ISO 228-1 | DIN |
other types of thread upon request
Modelo y especificación
There are three different designs:Additional special devices available upon request
*Resistance thermometer for device group II, category (1) 2 (GII cat. (1) 2)
Diagrama de flujo volumétrico
Los diagramas de flujo volumétrico han sido determinados con un banco de pruebas de caudal calibrado y certifi - cado por TÜV. El flujo volumétrico V. en [m³/h] y el CFH se refi eren a las condiciones estándar de referencia de aire según ISO 6358 (20°C, 1bar). La conversión a otras densidades y temperaturas están referidas en el Vol. 1: “Fundamentos Técnicos”.